Boost Labcare Products



Nuve Horizontal Autoclaves (OT300/OT430/OT570/OT)

Nüve Horizontal Autoclaves are ideal for steam sterilizing packed or unpacked surgical and dental instruments, operation linen, glass, plastic, rubber and silicon materials, infusion liquids, microbiological cultures and medical waste.

Available in 4 sizes: 300 Litre, 430 Litre, 570 Litre and 710 Litre

Avaiable as Double Door: 430 Litre and 570 Litre

Quality Engineering

The chamber, steam jacket, door and the steam generator are made of 316L stainless steel and they are tested according to EN 285 and PED 93/72/EC. The chamber, jacket, door are insulated with rock wool and generator is insulated with glass wool. The door is operated with a pneumatic system and has required safety system. The programs cannot be operated if the door is not closed properly. In case of an obstruction on the door closing direction, the door stops automatically.

Pre-vacuum is also used for the pre-heating of the sterilization load. At the end of the sterilization phase, post-vacuum is needed to dry the sterilized load. For fast air removal from the chamber, a high capacity water ring pump is used.

Low Running Costs

  • Air Cooling system means no water consumption is used to cool down the steam.
  • Pneumatically controlled valves have a longer service life than electrically operated valves.  
  • Low noise vacuum pump has a long service life, reliable functioning, low energy and water consumption.

Operation Features

  • Easy to use touchscreen
  • The parameters of last 28 cycles are kept in the memory
  • As the requirement of EN 285 standard, there is also an independent control system besides the main control system. The main one controls the sterilization process and records characteristic operating parameters, while the second one controls and records only the data related to every cycle.
  • The control system also reminds the user to replace the gasket and the HEPA filter
  • Comprehensive self-diagnostic system
    • Vacuum period is exceeded
    • Steam discharging period is exceeded
    • Door lock is released during a cycle
    • Temperature or pressure sensor failure
    • Heater failure
    • Air detector failure
    • Leakage in the vacuum system
    • Power failure
    • High/Low steam pressure or Temperature in the chamber

Standard Features

  • Thermal printer as standard to record the temperature and pressure data of the cycle.
  • Automatic water feeding system - 200 litre water tank is supplied with the units.

Optional Extras

  • RS 232 Port And Software
  • Water Softening Unit
  •  Loading Chart 
  • Air compressor, 10 bar 50 liters

Discounted Boost Labcare Maintenance Service Contract available when purchased with this autoclave

Contact Us For Details